TRIADEO® Smart Hydrogen Sulfide Countermeasures for Installation in a Glove Box

What is TRIADEO® Smart?

TRIADEO® Smart is a hydrogen sulfide (H₂S) control device installed inside the glove box. By removing hydrogen sulfide and other harmful gases, it improves the working environment and enhances safety.
As a safety measure for glove boxes, it supports safety management during research and development of sulfide-based solid electrolytes and all-solid-state battery-related work.

リニアイオンソース3

Features

  • Simply install it inside the glove compartment to easily remove hydrogen sulfide (H₂S elimination) or organic solvents.
  • As a compact hydrogen sulfide countermeasure device, it can be installed in existing glove boxes in a space-saving manner.
  • This system allows for easy implementation of enhanced safety measures for glove boxes without requiring any special piping work.
  • In environments where low concentrations of hydrogen sulfide are generated, this product contributes to ensuring worker safety and improving the working environment.

Usage

  • Applications for H₂S control in the research and development process of sulfide-based solid electrolytes.
  • Measures to remove harmful gases during electrode material evaluation
  • As a safety measure for all-solid-state batteries, we are addressing the issue of hydrogen sulfide generated during the assembly and disassembly process.
  • Used as safety management equipment during battery stress testing.
  • It can be used as a hydrogen sulfide removal device in glove box environments where low concentrations of H₂S are generated.
  • Safety measures for research and development environments involving lithium-ion batteries, all-solid-state batteries, and next-generation rechargeable batteries.
  • Future applications are expected to include general use in research equipment utilizing sulfide-based materials.

Standard Specification

Processing air volume 4.2m3/h
Weight Approximately 1.6 kg
Size W86mm×D86mm×H290mm
Power supply 4.5W (5V, 0.9A) 100V → 5V AC adapter included
Filter Intake side, exhaust side
Remarks Type A: For hydrogen sulfide
Type B: For organic solvents