Energy Saving Proposal by Switching to Turbo Blowers

A turbo blower combines air foil bearing and high-efficiency impeller/moter (PMSM) technologies, helping it to cut electricity costs for wastewater treatment, maintenance costs and even initial setup costs.

Examples

  • A certain sanitation association

    Example photo

    Comparison of Expected Power Consumption

    Energy 19% SAVING Comparison of Energy Consumption: Energy 19% SAVING Existing blower Turbo blower

    Comparison of Noise Levels

    Low noise 14dB DOWN Comparison of Noise Levels: Low noise 14dB DOWN Existing blower 89dB Turbo blower 75dB

    Comparison of Weight

    Lightweight 63% DOWN Comparison of Weight: Lightweight 63% DOWN Existing blower 1,240kg Turbo blower 450kg

    Comparison of Installation Area

    Space 61% SAVING Comparison of Installation Area: Space 61% SAVING Existing blower 1,003mm
    ×
    2,845mm
    Turbo blower 850mm
    ×
    1,300mm
    Existing blower
    (Multistage turbo blower)
    Turbo blower
    (Model: MAX75-C060S1)
    Number of units installed 1 unit 1 unit
    Specified point 45m3/min x 60kPa
    Rated output 75kW 56kW
    Energy consumption 535,236kWh/yr 433,620kWh/yr
    Reduction (ratio) ▲ 101,616kWh/yr (19% saving)
  • A certain business association

    Example photo

    Comparison of Installation Area

    Space 81% SAVING Comparison of Installation Area: Space 81% SAVING Existing blower 1,760mm
    ×
    3,222mm
    Turbo blower 850mm
    ×
    1,300mm
    Existing blower
    (Single suction type, six stage turbo blower)
    Turbo blower
    (Model: MAX100-C060S1)
    Number of units installed 1 unit 1 unit
    Specified point 71m3/min x 53.9kPa
    Rated output 100kW 75kW
  • A certain beverage company

    Example photo

    Comparison of Expected Power Consumption

    Energy 31% SAVING Comparison of Energy Consumption: Energy 31% SAVING Existing blower Turbo blower

    Comparison of Noise Levels

    Low noise 6dB DOWN Comparison of Noise Levels: Low noise 6dB DOWN Existing blower 87dB Turbo blower 81dB

    Comparison of Weight

    Lightweight 28% DOWN Comparison of Weight: Lightweight 28% DOWN Existing blower 900kg Turbo blower 650kg

    Comparison of Installation Area

    Space 44% SAVING Comparison of Installation Area: Space 44% SAVING Existing blower 1,100mm
    ×
    1,800mm
    Turbo blower 850mm
    ×
    1,300mm
    Existing blower
    (Roots blower)
    Turbo blower
    (Model: MAX100-C060S1)
    Number of units installed 2 units 1 unit
    Specified point 53.5m3/min x 60kPa
    Rated output 90kW (45kW x 2 units) 75kW
    Energy consumption 817,600kWh/yr 565,020kWh/yr
    Reduction (ratio) ▲ 252,580kWh/yr (31% saving)
  • A certain paper manufacturer

    Example photo Example photo

    Comparison of Expected Power Consumption Area

    Energy 31% SAVING Comparison of Expected Power Consumption Area: Energy 31% SAVING Existing blower 498kW Turbo blower 346kW
    Existing blower
    (Roots blower)
    Turbo blower
    (Model: MAX250-C080S1)
    Number of units installed 5 units (3 operationg, 2 backup) 2 units
    Specified point 231.2m3/min x 53.9kPa
    Rated output 480kW (160kW x 3 units) 380kW (190kW x 2 units)
    Energy consumption 4,362,480kWh/yr 3,030,960kWh/yr
    Reduction (ratio) ▲ 1,331,520kWh/yr (31% saving)
  • A certain food company

    Example photo
    Turbo blower
    (Model: MAX150-C060S1)
    Number of units installed 4 units
    Specified point 111m3/min * x 50kPa
    Rated output 115kW/unit

    * Airflow per unit

    Illustration Energy saving
    Low noise
    Easy airflow
    control
  • A certain paper manufacturer

    Example photo
    Turbo blower
    (Model: MAX150-C060S1)
    Number of units installed 4 units
    Specified point 78m3/min * x 80kPa
    Rated output 115kW/unit
    External dimensions (mm) W850 x L1,800 x H1,600
    Approx. main unit weight 810kg

    * Airflow per unit

    Illustration Energy saving
    Low noise/vibration
    Controlling number of
    units and airflow
    from central control unit
  • A certain paper manufacturer

    Example photo
    Turbo blower
    (Model: MAX75-C060)
    Number of units installed 1 unit
    Specified point 46m3/min * x 60kPa
    Rated output 56kW
    External dimensions (mm) W850 x L1,300 x H1,350
    Approx. main unit weight 450kg

    * Airflow per unit

    Illustration Space saving
    Low noise
    Can be installed outdoors
    in a simple building

Please contact our sales department for further details on TurboMAX blowers.